Kit extensible boiler gas hose and stainless water 200 400 mm 2 1/2 "n 3 3/4 '' 200/400 mm mega promoestensibile unisuper UNI 11353 DM 174 white

Kit extensible boiler gas hose and stainless water 200 400 mm 2 1/2 "n 3 3/4 '' 200/400 mm mega promoestensibile unisuper UNI 11353 DM 174 white

18,01 [+22% VAT]

  € 18,96 [+22% VAT]


REQUEST COST BEFORE PAYMENT


 

RELATED PRODUCTS

 
 
 
 
 
Product code 60208
EAN 8028653602084
Category GAS HOSES
Brand MBM
Availability

Tip a friend

More questions ?

 
pin it

extensible boiler kit, flexible gas pipe and stainless water 200 400 mm n 2 1/2 "n 3 3/4 '' 200/400 mm mega promoestensibile stainless unisuper UNI 11353 DM 174 white with three identification rings use in steel boiler / kitchen kit boiler water flexible gas hose 200 400 mm n 2 1/2 "n 3 3/4 '' 200/400 mm extensible stainless unisuper UNI 11353 DM 174 white with three identification rings use in boiler steel / kitchen extensible hose connections from the gas supply / water to household appliances such as boilers. extensible flexible fitting, suitable for gas in accordance with the uni 11353, suitable for water according to the White dm with three identification rings use fireproof-toxic external protection sheath of heat-shrinkable polyolefin, approved for connections to the gas mains / water boilers, water heaters, etc.. flexible extensible joint, suitable for gas use secondo with regulations 11353 each, suitable for domestic water use. fireproof non-toxic external protection, polyolefin heat shrink insulation, approved connecting boiler and water heater to water and gas networks. max 35kv constructed in accordance with the legislation (uni cig 11353). http://www.mbmitalia.com/new/catalogoweb/gas/gas2.html technical characteristics (same for gas and water pipe tube): inner tube: made of stainless steel AISI 316L with parallel waves solubilised, din 15, thickness 0 , 21 male mm.racconto: made of stainless steel AISI 303, thread according uni 7/1 sealingly on filetto.canotto nut: made of stainless steel AISI 303, with milled torsion to external piana.protezione sealing seat: the sheath is made of fireproof composite material (only for yellow gas pipe and white water pipe) .guarnizioni: according to UNI EN swivel 549dado rubber: made of stainless steel according to UNI EN 10088 / 2 or brass according to EN 12164, the second thread 228/1 uni not sealed on the thread. warnings 1) all appliances must operate with grounding (46/90) 2) avoid the installation in environment with atmosphere of chlorinated substances 3) avoid twisting and bumps during transport and assembly. 4) extend the hose by pulling it from both end fittings 5) does not extend beyond the measure indicated on the fittings. 6) Carefully follow the instructions for installation retroindicate. 7) for the cleaning of the pipe, use exclusively by rinsing soapy water then with tap water. 8) to change the seals whenever the tube were to be remounted. 9) make increasing use authorized installers. 10) It is prohibited to the connection of several pipes between them. warranty void if not the above warnings were met, the guarantee will fall auto-mind. instructions for mounting the gas pipe (the same applies to water) 1) starting work by closing the main gas shut-off valve (or water). 2) extend the hose up to the extent necessary, limiting the maximum length engraved on the fittings. 3) for female / female type (fg.fg) first connect the hose to the air, by inserting the seal in ' special seat and manually tighten in a clockwise direction one of the dice without tightening. subsequently connect the other end of the tube to the shut-off valve using the same procedimento.per male / female type (mf.fg.) first connect the tap to the male fitting, previously applying on the thread a few turns of teflon and manually screwing in the nut clockwise without tightening. 4) positioning the appliance definitively, so that there are kinks or twists on the tube with a radius less than 60 mm. 5) definitively tighten both end fittings using wrench 22 mm for the male fitting and fixing key. 6) open the tap of the gas shut-off (or water) and check the tightness of connections by means of l ' Use soapy water to be applied on the unions themselves. the eventual formation of bubbles shows the gas leak. in such a case check the tightness of the fittings and subsequently proceed to a further control. disassembly 1) proceed in the opposite direction to the first closing the stopcock. 2) first unscrew the swivel nut and then the male fitting. known techniques the flexible gas pipe, in accordance with un1 11353 (water DM 174), continuous wall in stainless steel AISI 316l thickness of not less than mm. 0.21 is suitable for domestic use of gas distribution (or water), in accordance with standards UNI EN 437, besides the applicable legal requirements in this field. It requires no maintenance. in conditions of use, pay attention to the minimum radius of curvature, male evil hi speed steel AISI 303 stainless hi speed STL AISI 303 male thread male thread according to UNI EN 10226-2 According UNI EN 10226-2 shank portadado shanklenght bringnut hi speed steel AISI 303 stainless hi speed STL AISI 303 nut nut hi speed steel AISI 303 stainless hi speed STL AISI 303 nut thread nut thread according to UNI EN iSO 228-1 according UNI EN iSO 228-1 diameter - diameter DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 gas use - gas use 0.5 bar 0.5 bar 0.5 bar 0.5 bar 0.5 bar 0.5 bar water use - water use 8 bar 8 bar 8 bar 5 bar 5 bar 5 bar table maximum operating pressure - maximum working pressure schedule diameter - diameter DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 minimum radius in millimeters - minimum radius in mm. 30 40 45 50 55 60 5 bar use water - water use 8 bar 8 bar 8 bar 5 bar 5 bar 5 bar table maximum operating pressure - maximum working pressure schedule diameter - diameter DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 minimum radius in millimeters - minimum radius in mm. 30 40 45 50 55 60 5 bar use water - water use 8 bar 8 bar 8 bar 5 bar 5 bar 5 bar table maximum operating pressure - maximum working pressure schedule diameter - diameter DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 minimum radius in millimeters - minimum radius in mm. 30 40 45 50 55 60

Registered users can share their experience with this product. Register to access all of the benefits reserved to registered users or click on login if you are already registered.